Subject: Technical Support Needed for CAROB08 - Modbus Communication Issues:
Message:
Hello,
I am trying to integrate the Eletechsup CAROB08 8-channel RS485 controller into my system. I have successfully verified my physical connection and RS485 converter using a broadcast command (Slave ID 0), but I cannot get any response (Timeout error) for read/write requests with any other Slave ID.
Could you please provide the following information to help me resolve this:
Default Communication Parameters: Are there any non-standard settings for this specific hardware? (e.g., Baud Rate, Parity, Stop bits, or Slave ID).
Modbus Protocol Map: Could you provide the detailed Modbus Register Map (Address list) for this specific firmware version?
Inter-frame Delay: Does this device require a specific inter-frame delay or timeout setting in the master software to respond correctly?
Test Software: Is there a specific configuration tool or test software that you recommend for this module?
I have tried 9600-8-N-1, 9600-8-E-1, and 8-N-2 with no success. I am using Modbus Poll for testing.
Thank you for your assistance.Eletechsup:1. The default baud rate is 9600-8-N-1.
2. We recommend testing the RS485 port first.
3. Set the first DIP switch (A0) to ON, and the others to OFF.
4. We recommend using a serial port assistant to send commands for testing.
5. If it still doesn't work properly, please send us a video for analysis.