N223B08 FAQ

Q: Dear Eletechsup customer service,   I am writing to inquire about the operating voltage specifications for your product, "DC12V 8CH 2 IN 1 RS232/TTL232 PC UART Relay Module Serial Pport Remote Control Switch For PLC Camera Industrial Control System"   N223B08 DC12V 8CH 2 IN 1 RS232/TTL232 PC UART Relay Module Serial Pport Remote Control Switch For PLC Camera Industrial Control System [N223B08_R] - US$25.99 : Eletechsup   According to the product documentation, the operating voltage is listed as 12V, but I would like to confirm the following details:   1. What is the acceptable input voltage range for the product? (e.g., XXV to XXV) 2. Can the product operate safely when directly connected to a car battery? For example, when the engine is running, the voltage may range between 13.8V and 14.4V. I would like to know if the product can function without issues under these conditions.   I would appreciate your guidance on this matter to ensure proper and safe usage of the product.   Thank you for your assistance, and I look forward to your response.   A: Can be powered by 12V battery. 12-18V can be...

N223B08 FAQ

Q: Dear Eletechsup customer service,   I am writing to inquire about the operating voltage specifications for your product, "DC12V 8CH 2 IN 1 RS232/TTL232 PC UART Relay Module Serial Pport Remote Control Switch For PLC Camera Industrial Control System"   N223B08 DC12V 8CH 2 IN 1 RS232/TTL232 PC UART Relay Module Serial Pport Remote Control Switch For PLC Camera Industrial Control System [N223B08_R] - US$25.99 : Eletechsup   According to the product documentation, the operating voltage is listed as 12V, but I would like to confirm the following details:   1. What is the acceptable input voltage range for the product? (e.g., XXV to XXV) 2. Can the product operate safely when directly connected to a car battery? For example, when the engine is running, the voltage may range between 13.8V and 14.4V. I would like to know if the product can function without issues under these conditions.   I would appreciate your guidance on this matter to ensure proper and safe usage of the product.   Thank you for your assistance, and I look forward to your response.   A: Can be powered by 12V battery. 12-18V can be...

RS485 based FAQ

Q: Rs485 based. 8 channel k-type thermocouple board? What about their latency, accuracy and reliability? Does your modules work on noisy industrial environment A: 1 “8 channel k-type thermocouple board” This product needs to be customized.2 As for stability and...

1 comment

RS485 based FAQ

Q: Rs485 based. 8 channel k-type thermocouple board? What about their latency, accuracy and reliability? Does your modules work on noisy industrial environment A: 1 “8 channel k-type thermocouple board” This product needs to be customized.2 As for stability and...

1 comment

WG18A02 FAQ

Q: this is code im using  import time import serial import binascii       ser = serial.Serial(         port='/dev/ttyS0',         baudrate = 9600,         parity=serial.PARITY_NONE,         stopbits=1,         bytesize=serial.EIGHTBITS,         timeout=1 )   while 1:     ser.write(b'\x01\x03\x00\x00\x00\x03\x05\xCB')     x=ser.readline()        hex_string = binascii.hexlify(x).decode('utf-8')     res= str(hex_string)     print(res) its Python  im connecting Raspberry Pi4 to UART (serial0) pins and this script give me answer \x7f~\xbe\xff\xff\xfb\xff\xf9\x7f\t   A :...

WG18A02 FAQ

Q: this is code im using  import time import serial import binascii       ser = serial.Serial(         port='/dev/ttyS0',         baudrate = 9600,         parity=serial.PARITY_NONE,         stopbits=1,         bytesize=serial.EIGHTBITS,         timeout=1 )   while 1:     ser.write(b'\x01\x03\x00\x00\x00\x03\x05\xCB')     x=ser.readline()        hex_string = binascii.hexlify(x).decode('utf-8')     res= str(hex_string)     print(res) its Python  im connecting Raspberry Pi4 to UART (serial0) pins and this script give me answer \x7f~\xbe\xff\xff\xfb\xff\xf9\x7f\t   A :...

ES30E08 FAQ

 Q: 10IOA04 : https://485io.com/index.php?main_page=advanced_search_result&search_in_description=1&keyword=10IOA04 . The link to the board you sent me is a card with 4 inputs and 4 outputs that needs to be connected to a PLC...

ES30E08 FAQ

 Q: 10IOA04 : https://485io.com/index.php?main_page=advanced_search_result&search_in_description=1&keyword=10IOA04 . The link to the board you sent me is a card with 4 inputs and 4 outputs that needs to be connected to a PLC...

N4AIA04 FAQ

Q:  we connect sensor 0-20MA with Port C1 Out range sensor 0-50mbar and 4-20mA how can adjust your card read 4-20mA A: The C1/C2 port can directly read the current value of 0-22MA. The unit is 0.1MA. For example: if the reading result is 100, then it is 10.0MA  

N4AIA04 FAQ

Q:  we connect sensor 0-20MA with Port C1 Out range sensor 0-50mbar and 4-20mA how can adjust your card read 4-20mA A: The C1/C2 port can directly read the current value of 0-22MA. The unit is 0.1MA. For example: if the reading result is 100, then it is 10.0MA  

LR12A01 FAQ

Q: Ciao! Posso ricevere più informazioni in merito? Non capisco!  Nello schema 2 il collegamento viene fatto con i pin "set e reset" in parallelo, ma nelle note c'è scritto che non si devono alimentare i pin "set/reset simultaneamente, quindi o si può (vedi schema 2) o le informazioni sullo schema 2 sono errate, nello schema indipendentemente da quale pulsante si da l'impulso, arriva il segnale negativo su GND, SET e RESET simultaneamente, la domanda è,  si può o non si può usare quello schema per fare funzionare il modulo in modalità keep quiescient current = 0? A: Dear friend, 1 When no button is pressed, the power GND is not connected, and the power supply will not have power output, so it is 0UA standby. 2 When the B1 button is pressed, the power GND is connected, and a low-level trigger signal is given to the "RESET" port. At this time, the "SET" port is disconnected. 3 When the B2 button is pressed, the power GND is connected, and a low-level trigger signal is given to the "SET" port. At this time, the "RESET" port is disconnected.   Q: Dear friend, in the wiring diagram number 2, so how is, if...

LR12A01 FAQ

Q: Ciao! Posso ricevere più informazioni in merito? Non capisco!  Nello schema 2 il collegamento viene fatto con i pin "set e reset" in parallelo, ma nelle note c'è scritto che non si devono alimentare i pin "set/reset simultaneamente, quindi o si può (vedi schema 2) o le informazioni sullo schema 2 sono errate, nello schema indipendentemente da quale pulsante si da l'impulso, arriva il segnale negativo su GND, SET e RESET simultaneamente, la domanda è,  si può o non si può usare quello schema per fare funzionare il modulo in modalità keep quiescient current = 0? A: Dear friend, 1 When no button is pressed, the power GND is not connected, and the power supply will not have power output, so it is 0UA standby. 2 When the B1 button is pressed, the power GND is connected, and a low-level trigger signal is given to the "RESET" port. At this time, the "SET" port is disconnected. 3 When the B2 button is pressed, the power GND is connected, and a low-level trigger signal is given to the "SET" port. At this time, the "RESET" port is disconnected.   Q: Dear friend, in the wiring diagram number 2, so how is, if...