{"product_id":"amdib16-amioa08-amrod08-amdoc16-dc-12v-24v-8di-8do-16di-16do-rs485-isolated-communication-digital-npn-pnp-input-and-output-modbus-rtu-plc-expansion-board","title":"AMDIB16 AMIOA08 AMROD08 AMDOC16 DC 12V 24V 8DI-8DO 16DI 16DO RS485 Isolated communication Digital NPN PNP Input and Output MODBUS RTU PLC Expansion Board","description":"\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003e\u003cspan style=\"font-size:22px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003eProduct Name: \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003e\u003cspan style=\"font-size:22px\"\u003eDC 12V 24V 8DI-8DO 16DI 16DO RS485 Isolated communication Digital NPN PNP Input and Output MODBUS RTU PLC Expansion Board\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e \u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003ePackage inlcuded:\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e1 PCS DC 12V 24V DI-DO RS485 Digital Input \u0026amp; Output IO Module(Please select the version you need)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n\u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Se1e2fd7beb174b20ad6f93fdb1768fadj.jpg\"\u003e\n\u003c\/div\u003e \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e \u003c\/div\u003e \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e \u003c\/div\u003e \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e\u003cstrong\u003e1 Product description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e8\/16ch optoelectronic isolation digital input channel (NPN\/PNP Low level input)\u003cbr\u003e8\/16ch optoelectronic isolation digital output channel (ULN2803 NPN output)\u003cbr\u003eRS485 MODBUS RTU standard communication protocol\u003cbr\u003eNetted with configuration software, PLC or industry touch panel\u003cbr\u003eCommunication circuit designed for thunder protection and interference immunity\u003cbr\u003eUsed for signal collection and control in industrial field\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e\u003cstrong\u003e2 Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e1 Working voltage: DC 7-25V (9V 12V 24V)\u003cbr\u003e2 Working current: 8-50MA\u003cbr\u003e3 8 optically isolated input ports (NPN active low)\u003cbr\u003e4 8 Darlington tube outputs (ULN2803 NPN output), the maximum load current of each channel is 300MA\u003cbr\u003e5 RS485 communication isolation protection 3000VDC, DI digital input port isolation protection 3000VDC\u003cbr\u003e6 Standard MODBUS RTU command (function code, 05\/06\/15\/16 Write, 01\/02\/03 Read )\u003cbr\u003e7 Baud rates: 1200 2400 4800 9600 (default) 19200 38400 57600 115200\u003cbr\u003e8 Parity bits: None (default) \/Even \/Odd\u003cbr\u003e9 Installation method Standard DIN rail installation\u003cbr\u003e10 Dimensions 125×70×30mm\u003cbr\u003e11 Weight: 114 grams\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e\u003cspan style=\"color:rgb(0, 0, 255)\"\u003e\u003cstrong\u003e3 Interface definition(8I8O):\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e\u003cspan style=\"color:rgb(0, 0, 255)\"\u003eVCC : Power input+\u003cbr\u003eGND: Power input-\u003cbr\u003eDO1: digital output channel 1\u003cbr\u003eDO2: digital output channel 2\u003cbr\u003eDO3: digital output channel 3\u003cbr\u003eDO4: digital output channel 4\u003cbr\u003eDO5: digital output channel 5\u003cbr\u003eDO6: digital output channel 6\u003cbr\u003eDO7: digital output channel 7\u003cbr\u003eDO8: digital output channel 8\u003cbr\u003eDI1 : Digital input channel 1\u003cbr\u003eDI2 : Digital input channel 2\u003cbr\u003eDI3 : Digital input channel 3\u003cbr\u003eDI4 : Digital input channel 4\u003cbr\u003eDI5 : Digital input channel 5\u003cbr\u003eDI6 : Digital input channel 6\u003cbr\u003eDI7 : Digital input channel 7\u003cbr\u003eDI8 : Digital input channel 8\u003cbr\u003eA+: RS485 signal A+\u003cbr\u003eB-: RS485 signal B-\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e \u003cdiv style=\"font-size:14pt\"\u003e \u003cdiv\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003eFor more information, please contact me\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003ePLC Output expansion board\u003cbr\u003eSmart Home,Home Automation ,Wiser Home;\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003ePTZ CCTV Camera\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003eSecurity Monitoring\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003eIdentification system;\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003eMotor FW \u0026amp; BW\u003cbr\u003eAutomatic curtain control\u003cbr\u003e\u003cbr\u003e1 Digital Input Wiring Diagram\u003cbr\u003e2 Digital output wiring diagram\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003eNote: The Darlington tube has only two states of ''high resistance'' and ''conduction'', and the output level cannot be measured with a multimeter.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S74e279da52aa487fb5c4e8db23c75b47J.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003eRS485 Networking Diagram\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S239c8749c0c6437e98b3103b6d2eb119F.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan new=\"\" style=\"font-family:\" times=\"\"\u003eModbus Rtu Register:\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sf1e0ca43051e48499f51a5ac92e1fd1dU.jpg\"\u003e\n\u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eletechsup Factory store ","offers":[{"title":"AMDIB16_NPN","offer_id":46474116038813,"sku":"AMDIB16_NPN","price":25.57,"currency_code":"USD","in_stock":true},{"title":"AMDIB16_PNP","offer_id":46474116071581,"sku":"AMDIB16_PNP","price":25.57,"currency_code":"USD","in_stock":true},{"title":"AMIOA08","offer_id":46474116104349,"sku":"AMIOA08","price":25.56,"currency_code":"USD","in_stock":true},{"title":"AMDOC16","offer_id":46474116137117,"sku":"AMDOC16","price":25.5,"currency_code":"USD","in_stock":true},{"title":"AMROD08","offer_id":46474116169885,"sku":"AMROD08","price":32.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/8622\/0189\/files\/S22b81c80c5254ff5bead8e7a23651044v.webp?v=1738857165","url":"https:\/\/eletechsup.com\/es\/products\/amdib16-amioa08-amrod08-amdoc16-dc-12v-24v-8di-8do-16di-16do-rs485-isolated-communication-digital-npn-pnp-input-and-output-modbus-rtu-plc-expansion-board","provider":"Eletechsup Ready Stock Factory Store 6-10days to Worldwide","version":"1.0","type":"link"}