{"product_id":"ce030-dc-5v-12v-24v-multifunction-delay-relay-time-switch-turn-on-off-plc-module","title":"CE030 DC 5V 12V 24V Multifunction Delay Relay Time Switch Turn on\/off PLC Module","description":"\u003cdiv style=\"font-family: Arial, Verdana, sans-serif; font-size: 12px;\"\u003e\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cstrong\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eTypical applications:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eHome lighting system\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eRemote control switch\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eRemote locking\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eSmart Home \/ Home Automation\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eLED lighting\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFluorescent lamp\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eDC Motor\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFluorescent lamp\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eAutomotive electronics\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003ePLC\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eIndustrial automation and control\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word; color: rgb(0, 0, 0); font-family: arial;\"\u003e\n\u003cdiv style=\"overflow-wrap: break-word;\"\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"overflow-wrap: break-word;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"font-size: 18px;\"\u003e1 DC 5V\/12V24V control circuit,Wiring diagram below. \"LOAD\" may be LED lights, fans, motors and \u003c\/span\u003e\u003cspan style=\"font-size: 18px;\"\u003eother DC \u003c\/span\u003e\u003cspan style=\"font-size: 18px;\"\u003e5V\/12V24V\u003c\/span\u003e\u003cspan style=\"font-size: 18px;\"\u003e equipment\u003c\/span\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-family: Arial, Verdana, sans-serif; font-size: 12px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"font-size: 18px;\"\u003e2 DC 1-48V OR AC 85-265V control circuit,Wiring diagram below(Note:If not DC \u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0); font-size: 18px;\"\u003e5V\/12V24V \u003c\/span\u003e\u003cspan style=\"font-size: 18px;\"\u003eload, need another \u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0); font-size: 18px;\"\u003e5V\/12V24V \u003c\/span\u003e\u003cspan style=\"font-size: 18px;\"\u003epower supply). \"LOAD\" may be LED lights, fans, motors and other DC AC equipment\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-family: Arial, Verdana, sans-serif; font-size: 12px;\"\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-family: Arial, Verdana, sans-serif; font-size: 12px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"font-size: 18px;\"\u003eProduct Name:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#000000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"font-size: 14pt;\"\u003eDC 5V 12V 24V Multifunction Delay Relay Time Switch Turn on\/off PLC Module\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\n\u003cdiv style=\"font-family: Arial, Verdana, sans-serif; font-size: 12px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"font-size: 14pt;\"\u003ePackage inlcuded:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"font-family: Arial, Verdana, sans-serif; font-size: 12px;\"\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-family: Arial, Verdana, sans-serif; font-size: 12px;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan font-size:=\"\" new=\"\" times=\"\"\u003e1 PCS 1channel multi-function delay relay board\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e(You can select 5V\/12V\/24V \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003eversion)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e  \u003c\/span\u003e\u003cimg src=\"https:\/\/i.ebayimg.com\/00\/s\/MTA1MFgxMDUw\/z\/GeEAAOSwJQBgXZri\/$_10.JPG\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-family: Arial, Verdana, sans-serif; font-size: 12px;\"\u003e\n\u003cdiv style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan new=\"\" times=\"\"\u003e\u003cspan style=\"font-size: 18pt;\"\u003eDescription:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv color:=\"\" new=\"\" style=\"font-size: 14pt;\" times=\"\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eCE030 multifunction relay control module, designed specifically for a variety of users with different needs, the use of micro-controller as the primary\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eControl unit, preset 18 kinds of functions, and can be based on user needs, customize and add other specific functions.\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eGenuine high quality power relay modules, high power high-voltage transistor, red, blue signal lights, military grade double-sided\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003ePCB board, cloth board to consider a comprehensive, stable performance, can be widely used in a variety of power control type applications.\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFeatures:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 112, 192);\"\u003e1 new upgrade to version 3.0, the module functions by eight kinds before, increased to 18 kinds, to meet the needs of more applications;\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 112, 192);\"\u003e2 increase supply anti-reverse feature, power will not damage the module wrong;\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 112, 192);\"\u003e3 uses top-quality high-voltage power supply modules, discrete power supply before replacing the system more stable and reliable;\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 112, 192);\"\u003e4 increased 0.1 seconds timing, timing accuracy from the previous 0.1 seconds, upgrade to 0.01 seconds;\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 112, 192);\"\u003e5 increase in automatic power saving feature, users can independently set.\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 112, 192);\"\u003e6.Size:76x40x1.5mm(approx)\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003cimg src=\"https:\/\/i.ebayimg.com\/00\/s\/MTA1MlgxMTQ2\/z\/ZcoAAOSwX4Bct9iJ\/$_10.JPG\"\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cimg src=\"https:\/\/i.ebayimg.com\/00\/s\/NDMxWDE0NTY=\/z\/UQ4AAOSwYbJct9iI\/$_10.JPG\"\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eModule Functions:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eTips: Function 1-8 on power-up self-start function 9-18 require low pulse signa l (low duration is shorter than 20ms, hereinafter the same) trigger the start.\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 1:\u003cspan style=\"font-size: 14pt;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eTiming Pick: After power, time delay relay pull T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a low level pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 2:\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eTiming off: when the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a low level pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 3:\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eTiming pull off again: After power relay to not pull, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 in 0.1 seconds -270 hours between adjustable, CH1 interface to a\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003elow pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 4:\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eTiming and then pull off: After power, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, -270 hour in 0.1 seconds delay time between T1 and T2 adjustable to CH1 interface a low pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 5:\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eInfinite loop timing mode 1: After power relay to not pull, after the delay time T1 reaches the relay is energized; pull the relay off after time T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 adjustable between second -270 hours, giving a low level pulse signal CH1 interface, you can restart the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 6:\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eInfinite loop timing mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting time T2 relay, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, giving a low level pulse signal CH1 interface, you can restart the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e \u003cspan style=\"font-size: 14pt;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 7:\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFinite loop timing mode 1: 5 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a low pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 8:\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFinite loop timing mode 2: 6, on the basis of the function, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a low pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 9:\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eLatching relay modes: CH1 interface to relay a low level pulse signal, relay, give a low pulse signal relay disconnected.\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 10:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eTrigger relay modes: CH1 interface to a low signal relay, relay, low disappear, relay disconnected.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 11:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003ePull the trigger timing: After power relay does not act, a low-level interface to CH1 pulse signal, the delay time relay pull T1, T1 between 0.1 seconds -270 hours adjustable, repeating a low level interface to CH1 pulse signal, repeat the above function;\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 12:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eTrigger timing off: After power relay does not act, a low-level interface to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 interface a low pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 13:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003ePull the trigger timing then disconnect: After power relay does not act, CH1 interface to a low level pulse signal, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 between 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\n\u003cdiv style=\"font-size: 14pt;\"\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 14pt;\"\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 14:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eDisconnect and then pull the trigger timing: After power relay does not act, a low-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 15:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eInfinite loop timing mode 1: After power relay does not operate to a low level pulse signal CH1 interface, the delay time T1 reaches the relay is energized; pull off the relay arrival time T2, and then repeat the above condition, the extension when the time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 16:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eInfinite loop timing mode 2: After power relay does not act, a low-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; break time T2 after reaching relay, then repeat the above condition, the delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 17:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eFinite loop timing mode 1: 15 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a low pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e \u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003eFunction 18:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv background-color:=\"\" font-size:=\"\" new=\"\" style=\"color: rgb(255, 0, 0);\" times=\"\"\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eFinite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a low pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 14pt;\"\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 176, 240); font-size: 14pt;\"\u003eConnections:\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 176, 240); font-size: 14pt;\"\u003eModule control side: there are 3-wire interface, all interfaces are terminal\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 14pt;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 176, 240);\"\u003e1, DC +:\u003c\/span\u003e\u003cspan style=\"color: rgb(0, 176, 240);\"\u003epower\u003c\/span\u003e\u003cspan style=\"color: rgb(0, 176, 240);\"\u003e positive\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 14pt;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 176, 240);\"\u003e2, DC-: power in negative\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 14pt;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 176, 240);\"\u003e3, CH1: Input Detection Interface\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 14pt;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 176, 240);\"\u003eRelay outputs: a 3-wire interface, all interfaces are terminal\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 14pt;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 176, 240);\"\u003e1, NO: normal open (before relay closes, this pin is not connected. after relay closes, the pin short-connects with COM)\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 14pt;\"\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 176, 240);\"\u003e2, COM: Relay Common Interface\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"color: rgb(0, 176, 240); font-size: 14pt;\"\u003e3, NC: Normal closed (before relay closes, this pin short-connect with COM. after relay closes, the pin is not connected )\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cdiv style=\"font-size: 14pt;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e\u003cspan style=\"font-size: 14pt;\"\u003eModule Size\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e1. Dimensions : 76mm *40mm * 20mm (L* W * H);\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e2. Screw Size: 3.0mm.\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e3. Screw holes center distance: 69mm * 33mm\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e\n\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e \u003c\/span\u003e\u003cimg src=\"https:\/\/i.ebayimg.com\/00\/s\/NjI3WDk2MQ==\/z\/GcsAAOSwkNFctqSA\/$_10.JPG\"\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\u003cspan style=\"font-family:times new roman,times,serif;\"\u003e \u003c\/span\u003e\u003cimg src=\"https:\/\/i.ebayimg.com\/00\/s\/NTAxWDk3OA==\/z\/6NEAAOSwAoJctqSA\/$_10.JPG\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003clink href=\"https:\/\/s.pushauction.com\/tl\/fd05376a72c44b31b0a570da1c145220\/180816033503.css\" rel=\"stylesheet\"\u003e\n\u003clink href=\"https:\/\/s.pushauction.com\/pm\/a44852fb1b9046b5b5822d4f3c085ff0\/9a6f0d6bbf004bdebaf5bf36ef3bfce2\/180816033503.css\" rel=\"stylesheet\"\u003e\n\u003cmeta content=\"target-densitydpi=device-dpi, width=device-width, initial-scale=1.0, minimum-scale=1.0, maximum-scale=1.0, user-scalable=yes\" name=\"viewport\"\u003e\n\u003cdiv id=\"pa_t_cp\"\u003e\n\u003cdiv class=\"cp_h\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!--PA4_HTMLBottom_End--\u003e","brand":"Eletechsup Original Factory Official‌ Store ","offers":[{"title":"24V","offer_id":46536972009629,"sku":"CE030_24V","price":3.99,"currency_code":"USD","in_stock":true},{"title":"12V","offer_id":46536972042397,"sku":"CE030_12V","price":3.99,"currency_code":"USD","in_stock":true},{"title":"5V","offer_id":46536972075165,"sku":"CE030_5V","price":3.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/8622\/0189\/files\/10_ad0fbbb6-7199-4305-85d9-d2d59d6ee90e.jpg?v=1740744983","url":"https:\/\/eletechsup.com\/es\/products\/ce030-dc-5v-12v-24v-multifunction-delay-relay-time-switch-turn-on-off-plc-module","provider":"Eletechsup Ready Stock Factory Store 6-10days to Worldwide","version":"1.0","type":"link"}