{"product_id":"io22c01-dc-12v-high-trigger-multifunction-self-lock-relay-plc-cycle-timer-module-delay-time-switch","title":"IO22C01 DC 12V High-Trigger Multifunction Self-lock Relay PLC Cycle Timer Module Delay Time Switch","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cspan data-spm-anchor-id=\"a2g0o.detail.1000023.i0.28039XWj9XWjC4\"\u003eIO22C01 from eletechsup \u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cspan data-spm-anchor-id=\"a2g0o.detail.1000023.i0.28039XWj9XWjC4\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cspan data-spm-anchor-id=\"a2g0o.detail.1000023.i0.28039XWj9XWjC4\"\u003eProduct Name:DC 12V High-Trigger Multifunction Self-lock Relay PLC Cycle Timer Module Delay Time Switch Board\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv data-spm-anchor-id=\"a2g0o.detail.1000023.i2.28039XWj9XWjC4\"\u003e\n\u003cbr\u003e \u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv data-spm-anchor-id=\"a2g0o.detail.1000023.i1.28039XWj9XWjC4\"\u003e\n\u003cbr\u003e \u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e \n\u003cdiv\u003e \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003ePackage inlcuded:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003e1 PCS DC 12V 10A \u003c\/span\u003eHigh Pulse Trigger 1 channel multi-function delay relay module\u003c\/div\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cimg height=\"800\" src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1dXmKMVXXXXcvXFXXq6xXFXXX0.jpg\" width=\"800\"\u003e\u003cbr\u003e\u003cimg height=\"1000\" src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1EgOwMVXXXXbEaXXXq6xXFXXXx.jpg\" width=\"1000\"\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eDescription:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eIO22C01\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emultifunction relay control module, designed specifically for a variety of users with different needs, the use of micro-controller as the primary\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eControl unit, preset 18 kinds of functions, and can be based on user needs, customize and add other specific functions.\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eGenuine high quality power relay modules, high power high-voltage transistor, red, blue signal lights, military grade double-sided\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003ePCB board, cloth board to consider a comprehensive, stable performance, can be widely used in a variety of power control type applications.\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFeatures:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e \n\u003cdiv\u003e\n\u003cbr\u003e1 new upgrade to version 3.0, the module functions by eight kinds before, increased to 18 kinds, to meet the needs of more applications;\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e2 Power is DC 12V\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e3 uses top-quality high-voltage power supply modules, discrete power supply before replacing the system more stable and reliable;\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e4 increased 0.1 seconds timing, timing accuracy from the previous 0.1 seconds, upgrade to 0.01 seconds;\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e5 increase in automatic power saving feature, users can independently set.\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e6.Size:66.5x37x19mm\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e7 Weight : 26 grams\u003c\/div\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eModule Functions:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eTips: Function 1-8 on power-up self-start function 9-18 require high pulse signal (high duration is shorter than 20ms, hereinafter the same) trigger the start.\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 1:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eTiming Pick: After power, time delay relay pull T1, T1 between 0.1 seconds -270 hours adjustable, IN interface to a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal, repeat the above functions;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 2:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eTiming off: when the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, IN interface to a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal, repeat the above functions;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 3:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eTiming pull off again: After power relay to not pull, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 in 0.1 seconds -270 hours between adjustable, CH1 interface to a\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epulse signal, repeat the above functions;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 4:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eTiming and then pull off: After power, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, -270 hour in 0.1 seconds delay time between T1 and T2 adjustable to CH1 interface a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epulse signal, repeat the above functions;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 5:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eInfinite loop timing mode 1: After power relay to not pull, after the delay time T1 reaches the relay is energized; pull the relay off after time T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 adjustable between second -270 hours, giving a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal CH1 interface, you can restart the above functions;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 6:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eInfinite loop timing mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting time T2 relay, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, giving a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal CH1 interface, you can restart the above functions;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 7:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFinite loop timing mode 1: 5 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epulse signal, the above functions can be re-started;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 8:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFinite loop timing mode 2: 6, on the basis of the function, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epulse signal, the above functions can be re-started;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 9:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eLatching relay modes: CH1 interface to relay a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal, relay, give a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epulse signal relay disconnected.\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 10:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eTrigger relay modes: CH1 interface to a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003esignal relay, relay,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elow\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003edisappear, relay disconnected.\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 11:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003ePull the trigger timing: After power relay does not act, a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e-level interface to CH1 pulse signal, the delay time relay pull T1, T1 between 0.1 seconds -270 hours adjustable, repeating a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel interface to CH1 pulse signal, repeat the above function;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 12:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eTrigger timing off: After power relay does not act, a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e-level interface to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 interface a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epulse signal, repeat the above functions;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 13:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003ePull the trigger timing then disconnect: After power relay does not act, CH1 interface to a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 between 0.1 seconds -270 hours adjustable, repeat CH1 interface to a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal, repeat the above functions;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 14:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eDisconnect and then pull the trigger timing: After power relay does not act, a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal, repeat the above functions;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 15:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eInfinite loop timing mode 1: After power relay does not operate to a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal CH1 interface, the delay time T1 reaches the relay is energized; pull off the relay arrival time T2, and then repeat the above condition, the extension when the time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal, the above functions can be re-started;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 16:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eInfinite loop timing mode 2: After power relay does not act, a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; break time T2 after reaching relay, then repeat the above condition, the delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003elevel pulse signal, the above functions can be re-started;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 17:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFinite loop timing mode 1: 15 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epulse signal, the above functions can be re-started;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFunction 18:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003eFinite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epulse signal, the above functions can be re-started;\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cimg height=\"800\" src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1.1qqMVXXXXcuaXXXq6xXFXXXx.jpg\" width=\"800\"\u003e\u003cbr\u003e\u003cspan\u003eConnections:\u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e \n\u003cdiv\u003e\n\u003cbr\u003eModule Voltage Signal Input:There have three interfaces, all interfaces have terminal,user easy to use.\u003c\/div\u003e\n \n\u003cdiv\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e1.GND : DC 12V Negative\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e2.12V : DC 12V Positive\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e3.IN1:Input signal interface. (2.5-24V high voltage to be valid; 0-0.6V low voltage to be invalid;0.7V-2.4V voltage is unpredictable,you should avoid this voltage range)\u003c\/div\u003e\n \n\u003cdiv\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003eModule Output: There have three interfaces, all interfaces have terminal.\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e1.NO : Normally open interface,the relay becomes vacant before, after pull-in short with the COM;\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e2.COM : Common interface;\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e3.NC : Normally closed interface, short with COM before, become vacant after pull-in.\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n \n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \n\u003cdiv\u003e \n\u003cdiv\u003e\n\u003cspan\u003e \u003c\/span\u003e\n\u003cdiv\u003e\n\u003cbr\u003eModule Size\u003c\/div\u003e\n\u003cspan\u003e \u003c\/span\u003e\n\u003cdiv\u003e\n\u003cspan\u003e \u003c\/span\u003e\n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n\u003cspan\u003e \u003c\/span\u003e\n\u003cdiv\u003e \n\u003cdiv\u003e\n\u003cbr\u003e1. Dimensions: 66.5mm * 37mm * 19mm (L * W * H);\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e2. Pore size : 2.5mm\u003c\/div\u003e\n \n\u003cdiv\u003e\n\u003cbr\u003e3. Weight : 26g\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eletechsup Factory store ","offers":[{"title":"Default Title","offer_id":46474291839133,"sku":"IO22C01_12V","price":4.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/8622\/0189\/files\/HTB1EF1sMVXXXXXFapXXq6xXFXXXr_29d754e9-e916-461f-be80-fd5f5227cb17.webp?v=1738859688","url":"https:\/\/eletechsup.com\/es\/products\/io22c01-dc-12v-high-trigger-multifunction-self-lock-relay-plc-cycle-timer-module-delay-time-switch","provider":"Eletechsup Ready Stock Factory Store 6-10days to Worldwide","version":"1.0","type":"link"}