{"product_id":"lr43a01-dc-12v-multi-function-magnetic-latchingkeep-impulse-relay-delay-time-switch-module-for-ups-battery-motor-led-ip-camera","title":"LR43A01 DC 12V Multi-function Magnetic Latching(keep) Impulse Relay Delay Time Switch Module for UPS Battery Motor LED IP Camera","description":"\u003cdiv class=\"nTab\"\u003e\n\u003cdiv class=\"TabContent\"\u003e\n\u003cdiv id=\"myTab1_Content0\"\u003e\n\u003cdiv id=\"productDescription\"\u003e\n\u003cdiv id=\"nav-description\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"extend--content--DlnAngg\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"description--product-description--nxRv0lW\" data-pl=\"product-description\" data-spm=\"1000023\" id=\"product-description\"\u003e\n\u003cdiv class=\"description--origin-part--SsZJoGC\"\u003e\n\u003cdiv class=\"detailmodule_html\"\u003e\n\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cspan data-spm-anchor-id=\"a2g0o.detail.1000023.i0.5866utj7utj74u\"\u003eLR43A01 from eletechsup\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cspan data-spm-anchor-id=\"a2g0o.detail.1000023.i0.5866utj7utj74u\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cspan data-spm-anchor-id=\"a2g0o.detail.1000023.i0.5866utj7utj74u\"\u003eProduct Name: DC 12V Multi-function Magnetic Latching(keep) Impulse Relay Delay Time Switch Module for UPS Battery Motor LED IP Camera\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003ePackage inlcuded:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e1 PCS 1channel \u003c\/span\u003eDC 12V Latching(keep) Multifunction Impulse Relay Module\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H62e2990d4b2747ac9171675ac88af74fO.jpg\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eWorking voltage: DC 12V(10-15V)\u003cbr\u003e\u003cspan\u003eWorking current : 7-8MA(Digital Tube is OFF)\u003cbr\u003eWorking current : 28-30MA(Digital Tube is ON)\u003cbr\u003eRelay switching current: 45MA (only lasts 0.3 seconds)\u003c\/span\u003e\u003cbr\u003eLoad current : AC 250V\/10A, DC 30V\/10A\u003cbr\u003e0.1 seconds -270 hours between adjustable\u003cbr\u003e18 functions can be selected(Function compatible with CE030 FRM01 Relay Module)\u003cbr\u003eD1 LED : Relay status indication: ON relay is on, OFF relay is off\u003cbr\u003ePWR LED: Input indicator,It will flash when power on or trigger.\u003cbr\u003eSize : 76 x 40 x 20mm\u003cbr\u003eWeight : 28g\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eUse must read:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e1 \u003c\/span\u003e\u003cspan\u003eFor more instructions, please contact me, or search for ''CE030\/FRM01\/LR43A01'' on GOOGLE. Their functional parameters are the same.\u003cbr\u003e\u003cbr\u003e2 Energy saving is relative to ordinary relay modules.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e3 In the working state, click the SET button to close the digital display, and click again to open the digital tube display.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e4 Press and hold the NUM+ button for 4-5 seconds. After 10 seconds, enter the energy-saving mode. Press and hold the NUM+ button again for 4-5 seconds to exit the energy-saving mode (this function can only be set when the digital tube is lit).\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eTypical applications:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eAutomotive electronics\u003cbr\u003eIndustrial automation and control\u003cbr\u003eIndustrial equipment\u003cbr\u003eMotor LED PLC\u003cbr\u003eIP Camera PTZ CCTV\u003cbr\u003eUPS Uninterruptible power supply\u003cbr\u003eSmart Home\u003cbr\u003eEmergency lighting\u003cbr\u003eMCU development board\u003cbr\u003eToy car\u003cbr\u003eHome lighting system\u003cbr\u003eRemote control switch\u003cbr\u003eRemote locking\u003cbr\u003eSmart Home \/ Home Automation\u003cbr\u003eLED lighting\u003cbr\u003eFluorescent lamp\u003cbr\u003eDC Motor\u003cbr\u003eFluorescent lamp\u003cbr\u003eAutomotive electronics\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H7a72c60edbd24998ab048eafe866250fE.jpg\"\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eConnections:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eModule control side: there are 3-wire interface, all interfaces are terminal\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e1, DC +:power positive\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e2, DC-: power in negative\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e3, CH1: Input Detection Interface\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eRelay outputs: a 3-wire interface, all interfaces are terminal\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e1, NO: normal open (before relay closes, this pin is not connected. after relay closes, the pin short-connects with COM)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e2, COM: Relay Common Interface\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eModule Functions:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003eTips: Function 1-8 on power-up self-start function 9-18 require \u003c\/span\u003elow pulse signa\u003cspan\u003el (low duration is shorter than 20ms, hereinafter the same) trigger the start.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 1:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eTiming Pick: After power, time delay relay pull T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a low level pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 2:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eTiming off: when the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a low level pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 3:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eTiming pull off again: After power relay to not pull, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 in 0.1 seconds -270 hours between adjustable, CH1 interface to a\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003elow pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 4:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eTiming and then pull off: After power, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, -270 hour in 0.1 seconds delay time between T1 and T2 adjustable to CH1 interface a low pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 5:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eInfinite loop timing mode 1: After power relay to not pull, after the delay time T1 reaches the relay is energized; pull the relay off after time T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 adjustable between second -270 hours, giving a low level pulse signal CH1 interface, you can restart the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 6:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eInfinite loop timing mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting time T2 relay, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, giving a low level pulse signal CH1 interface, you can restart the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 7:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFinite loop timing mode 1: 5 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a low pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 8:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFinite loop timing mode 2: 6, on the basis of the function, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a low pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 9:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eLatching relay modes: CH1 interface to relay a low level pulse signal, relay, give a low pulse signal relay disconnected.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 10:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eTrigger relay modes: CH1 interface to a low signal relay, relay, low disappear, relay disconnected.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 11:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003ePull the trigger timing: After power relay does not act, a low-level interface to CH1 pulse signal, the delay time relay pull T1, T1 between 0.1 seconds -270 hours adjustable, repeating a low level interface to CH1 pulse signal, repeat the above function;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 12:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eTrigger timing off: After power relay does not act, a low-level interface to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 interface a low pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 13:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003ePull the trigger timing then disconnect: After power relay does not act, CH1 interface to a low level pulse signal, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 between 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 14:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eDisconnect and then pull the trigger timing: After power relay does not act, a low-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, repeat the above functions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 15:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eInfinite loop timing mode 1: After power relay does not operate to a low level pulse signal CH1 interface, the delay time T1 reaches the relay is energized; pull off the relay arrival time T2, and then repeat the above condition, the extension when the time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 16:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eInfinite loop timing mode 2: After power relay does not act, a low-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; break time T2 after reaching relay, then repeat the above condition, the delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 17:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFinite loop timing mode 1: 15 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a low pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFunction 18:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eFinite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a low pulse signal, the above functions can be re-started;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H7a72c60edbd24998ab048eafe866250fE.jpg\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eModule Size\u003c\/div\u003e\n\u003cdiv\u003e1. Dimensions : 76mm *40mm * 20mm (L* W * H);\u003c\/div\u003e\n\u003cdiv\u003e2. Screw Size: 3.0mm.\u003c\/div\u003e\n\u003cdiv\u003e3. Screw holes center distance: 69mm * 33mm\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cimg height=\"627\" src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1mF4LJXXXXXbAXXXXq6xXFXXXj.jpg\" width=\"961\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ciframe class=\"extend--iframe--ZW0B1OE\"\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"clear\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mumbsimilar\"\u003e\n\u003ch2 class=\"centerBoxHeading\"\u003eRecommended products\u003c\/h2\u003e\n\u003c\/div\u003e","brand":"Eletechsup Factory store ","offers":[{"title":"Default Title","offer_id":46474128785565,"sku":"LR43A01","price":4.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/8622\/0189\/files\/He9a498f0a2074ce2a9de7a931a7b719c5.webp?v=1738857443","url":"https:\/\/eletechsup.com\/es\/products\/lr43a01-dc-12v-multi-function-magnetic-latchingkeep-impulse-relay-delay-time-switch-module-for-ups-battery-motor-led-ip-camera","provider":"Eletechsup Ready Stock Factory Store 6-10days to Worldwide","version":"1.0","type":"link"}