https://eletechsup.com/products/dc-12v-24v-1-2ch-din35-rail-rs485-ethernet-modbus-rtu-relay-board?variant=46538862690461 I have a question for you: *Can I control the relay simultaneously using Ethernet and RS485 (at the same time, sometimes sending commands to the relay via Ethernet, and sometimes via RS485)? Can I simultaneously control the relay using the Ethernet connector and the RS485 connector? My assumptions: Program number 1 on the computer is connected to relay number 1 via the Ethernet connector. Program number 2 on the computer is connected to relay number 1 via the RS485 connector. Program number 1 and program number 2 are running simultaneously on the computer. The signal to open the relay can be sent by either program number 1 or program number 2. Can the ETROB02 2DI-2DO work in this way? Answer : Yes. Ethernet and RS485 can work at the same time.
ETROB02 ETROA01 FAQ
https://eletechsup.com/products/dc-12v-24v-1-2ch-din35-rail-rs485-ethernet-modbus-rtu-relay-board?variant=46538862690461 I have a question for you: *Can I control the relay simultaneously using Ethernet and RS485 (at the same time, sometimes sending commands to the relay via Ethernet, and sometimes via RS485)? Can I simultaneously control the relay using the Ethernet connector and the RS485 connector? My assumptions: Program number 1 on the computer is connected to relay number 1 via the Ethernet connector. Program number 2 on the computer is connected to relay number 1 via the RS485 connector. Program number 1 and program number 2 are running simultaneously on the computer. The signal to open the relay can be sent by either program number 1 or program number 2. Can the ETROB02 2DI-2DO work in this way? Answer : Yes. Ethernet and RS485 can work at the same time.
ET69C02 FAQ
I managed to get the ET69C02 working using TCP client but I can't get it to work with HTTP client Answer : https://1drv.ms/u/c/f5c7cfff112f0ffe/Ef4PLxH_z8cggPU9EgAAAAABPMphRuw4H-y4A0qsJYQVGQ?e=UC8rdo https://youtu.be/olaK3FLNDgo Question : I followed this material and it worked. I just didn't see any example with http client. I tried to configure it and it doesn't work as shown in the image. Answer : Please follow the video completely, every parameter is the same. Answer : ...
ET69C02 FAQ
I managed to get the ET69C02 working using TCP client but I can't get it to work with HTTP client Answer : https://1drv.ms/u/c/f5c7cfff112f0ffe/Ef4PLxH_z8cggPU9EgAAAAABPMphRuw4H-y4A0qsJYQVGQ?e=UC8rdo https://youtu.be/olaK3FLNDgo Question : I followed this material and it worked. I just didn't see any example with http client. I tried to configure it and it doesn't work as shown in the image. Answer : Please follow the video completely, every parameter is the same. Answer : ...
ES32C14 FAQ
Hi, I buy the shield for esp32 (photo). But I connect Signal 4-20 ma, but the resistence that I see is for 90 ohms. The input in pins 34-35, etc.. has a suport Max range 3,3 v. But I get input 24 v dc (4-20ma), the Max Volts is 1,86 v. The resolution ADC is 11 bits. The great resistence mabe would be 165 ohms. Could you help me, if you have another Shield? I have a Big proyect. Thanks. Answer : Sorry! We don't have other expansion boards. But you can replace the resistors yourself.
ES32C14 FAQ
Hi, I buy the shield for esp32 (photo). But I connect Signal 4-20 ma, but the resistence that I see is for 90 ohms. The input in pins 34-35, etc.. has a suport Max range 3,3 v. But I get input 24 v dc (4-20ma), the Max Volts is 1,86 v. The resolution ADC is 11 bits. The great resistence mabe would be 165 ohms. Could you help me, if you have another Shield? I have a Big proyect. Thanks. Answer : Sorry! We don't have other expansion boards. But you can replace the resistors yourself.
wg18a02 FAQ
I have small problem to change adress of wg18a02 , I wabt to change it from1 to 4 But this is whatni receive And adres not changing I found it... strange. Write protection should be ON not Off Answer : WG18A02 turn off write protection Question What if i connected 2 from 10 wg18a02...
wg18a02 FAQ
I have small problem to change adress of wg18a02 , I wabt to change it from1 to 4 But this is whatni receive And adres not changing I found it... strange. Write protection should be ON not Off Answer : WG18A02 turn off write protection Question What if i connected 2 from 10 wg18a02...
NT18B07 FAQ
I bought it together with the NT18B07 ,The information is stored in the device for some time or only read instantly from the sensors Answer : only read instantly from the sensors
NT18B07 FAQ
I bought it together with the NT18B07 ,The information is stored in the device for some time or only read instantly from the sensors Answer : only read instantly from the sensors
ET69C02 FAQ
ET69C02 , Hi, we have a lot of your network modules connected to your relay modules. we have encountered an issue. The network modules loose their connection to the network. They start working fine after setup but in time just loose connection and there is not ping to them and no web interface, until you restart the network module, and sometimes even have to reset the module. We have tried to increase the voltage to 12.9-13.0 volts, but it did not work. This is our general configuration: Answer : 1 The power supply may be disturbed. Please use an independent DC 12V power supply 2 The network interface may be disturbed. Please change the network cable environment 3 If the problem still cannot be solved, please replace the ET69C02 board.
ET69C02 FAQ
ET69C02 , Hi, we have a lot of your network modules connected to your relay modules. we have encountered an issue. The network modules loose their connection to the network. They start working fine after setup but in time just loose connection and there is not ping to them and no web interface, until you restart the network module, and sometimes even have to reset the module. We have tried to increase the voltage to 12.9-13.0 volts, but it did not work. This is our general configuration: Answer : 1 The power supply may be disturbed. Please use an independent DC 12V power supply 2 The network interface may be disturbed. Please change the network cable environment 3 If the problem still cannot be solved, please replace the ET69C02 board.