1
/
of
2
Eletechsup Original Factory Official Store
1PCS Wireless Remote Relay RF Control Switch System 4PCS Receivers 433MHZ DC24V
1PCS Wireless Remote Relay RF Control Switch System 4PCS Receivers 433MHZ DC24V
Regular price
$35.98 USD
Regular price
$35.98 USD
Sale price
$35.98 USD
Unit price
/
per
Couldn't load pickup availability
1PCS Wireless Remote Relay RF Control Switch System 4PCS Receivers 433MHZ DC24V
QTY: 4 pcs 1 Channel receiver contrller and 1 pcs 4 button handsender . (This remote doesnot have a battery inside )
Receiver :
Technical indicators:
Operating frequency: 433.92MHz;
Receiver sensitivity:-95dB;
Encoding: Receiver Recording;
Momentary / Latch / Toggle selectable (defult is Momentary , Latch Mode need 2 buttons handsender );
Output mode : Relay switch;
Receiver size: 62 * 35 * 22 mm;
Encoding: Receiver Recording;
Momentary / Latch / Toggle selectable (defult is Momentary , Latch Mode need 2 buttons handsender );
Output mode : Relay switch;
Receiver size: 62 * 35 * 22 mm;
Max load : 500W;
Advantage :
1: Receiver Mother board have a learning key , if the remote is lost , must buy EV1527 remotes to re-learn;
Output:
Work mode (programmable )
singnal Inter-locking (Latch)
singnal Self-locking (Toggle)
singnal Non-locking (Momentary is defult )
Program steps :
1: keep pressing learning key on the receiver controller ,
LED turn on after 2 second , then turn off after 4 second, then the receiver controller enter programming state , but not release the finger , still keep pressing the learning button ,
LED blink once after 2 second , release the finger on learing key , it is Momentary mode ,
or still keep pressing learing key ,
LED blink twice after 2 second , release the finger on learing key , it is Toggle mode ,
or still keep pressing learing key ,
LED blink 3 times after 2 second , release the finger on learing key , it is Latch mode ,
Learning method and steps
Keep pressing learnig key on receiver controller board , LED turn on after 2 seconds , release the finger on learning key , press the key on remote , work state LED blink 3 times , it means learnig successfully ;
Clear the deposit information
Keep pressing learnig key on receiver controller board , LED turn on after 2 seconds , then turn off after 4 seconds , it means clearing successfully .
Relay mode :
Normally close (NC ) ;
Normally open (NO ) ;
- Normally-open (NO) contacts connect the circuit when the relay is activated; the circuit is disconnected when the relay is inactive. It is also called a Form A contact or "make" contact. NO contacts may also be distinguished as "early-make" or NOEM, which means that the contacts close before the button or switch is fully engaged.
- Normally-closed (NC) contacts disconnect the circuit when the relay is activated; the circuit is connected when the relay is inactive. It is also called a Form B contact or "break" contact. NC contacts may also be distinguished as "late-break" or NCLB, which means that the contacts stay closed until the button or switch is fully disengaged.
Transmitter :
Technical Data :
Operating voltage: 12V 23A (battery Replaceable);
Operating current: ≤ 9mA;
Oscillation mode: SAW resonator;
Modulation mode:ASK/OOK;
Operating frequency:433.92MHZ ;
Encoding format: PT2264 fixed code (compatiable for PT2262 SC2262 PT2260 );
RC Resistance : 4.7M;
Remote distance : 100-500meter ;