N4CRB04 4DI-4DO RS485 Pulse Counter Relay Remote IO Modbus Watchdog inching self-locking interlocking Delay PLC HMI IO Expansion

N4CRB04 4DI-4DO RS485 Pulse Counter Relay Remote IO Modbus Watchdog inching self-locking interlocking Delay PLC HMI IO Expansion

SKU:N4CRB04_12V

1000 in stock

Regular price $16.99
Regular price $21.39 Sale price $16.99
Sale Sold out

N4CRB04 Eletechsup is a multi-functional RS485 I/O module developed and manufactured by eletechsup. In addition to supporting the standard MODBUS RTU protocol, it also has several features not found in older versions, such as a watchdog timer to ensure automatic reset in case of device malfunction, and an input port counting function to ensure no input signals are missed.

The N4CRB04 is a multifunctional product:
1. Compatible with NPN/PNP level inputs
2. Counts input pulses (Registers 0x0020-0x0023)
3. Multiple relay control modes: inching, self-locking, and interlocking
(registers 0x0000-0x0003)
4. Watchdog function (register 0x00F3)
5 Remote IO function (registers 0x00F5-0x00F6)
6 Automatic reporting of digital input(DI) status(register 0x00F8)
7 Input and output relationship(DI-DO relationship)(register 0x00FA)

Features:
1: Operating Voltage: DC 12V/24V
2: Operating Current: Standby current (all relays closed) 12MA, 1 relay open 40MA, 2 relays open 68MA, 3 relays open 93MA,4 relays open 120MA
3: 4ch 3-24V NPN/PNP Opto-Isolated Input Ports
4: The input-output relationship can be set to various association modes through instructions(Self-lockingdefault)/Interlocking/Momentary/Interlocking/Output=Input)
5: The input port can remotely control the output port of another board through the RS485 bus
6: The input port has a counting function. It can count pulses greater than 100MS (the pulse width can be set from 10 to 2000MS).
7: Support standard Modbus RTU command, function code, write 05/06/15/16 read 01/02/03
8: With hardware reset function, with TVS anti-surge protection
9: 4 opto-isolated inputs (NPN), 4 relay outputs (upgraded relays, more durable)
10: MODBUS commands can be made serial HyperTerminal (serial assistant) OR ''Modbus Poll''Enter;
11: Under the MODBUS command mode, it can support up to 254 devices in parallel
12: The default baud rate is 9600BPS. The baud rate can be selected by Conmand 2400 4800 9600 19200 38400 57600 115200BPS
13: The parity can be none parity, even parity and odd parity
14: The data sending and returning time can be set,with a maximum value of 1000ms
15: Size: 73 * 72 * 19mm(Only PCB Board);76 * 82*40mm(with Din Rail Box)
16: Weight: 80g(Only PCB Board);142g(with Din Rail Box)
17: Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC


DIN rail Box parameters:
DIN rail Box parameters:
Product model: UM72
Color:Grey
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 73 mm PCB boards
Net weight: 61g
Installation: DIN35 and C45 rail

Glossary:
NO : Relay normally open contact
COM : Relay common contact
NC : Relay normally closed contact
Open : NO connection COM, NC disconnect COM
Close : NO disconnect COM, NC connection COM

Command Description, Please refer to''N4CRB04 MODBUS RTU Commamd''


Input port pulse counting function:
DI Counter (registers 0x0020-0x0023) :
Record the number of DI pulses greater than 100MS. Pulses less than 100MS will be ignored.
The initial value is 0 or set by the DI Counter Setting (0x0040-0x0043) Register.


DI Counter Setting (registers 0x0040-0x0043) :
If the written value is less than the DI Counter (0x0020-0x0023) value, the DI Counter value will automatically subtract the DI Counter Setting (0x0040-0x0043) value.
If the written value is greater than the DI Counter (0x0020-0x0023) value, the DI Counter value will be reset to 0

DI Counter Pulse Width (registers 0x0060-0x0063) :
The setting value is 0-199, unit is 10MS. Default value is 10. The pulse width can be set through this register.
For example: if the setting value is 10, pulses less than 100MS will be ignored, and pulses greater than 100MS will be counted.


How to set up remote control:
1The RS485 address and baud rate must be the same (it is recommended to restore both boards to factory settings).
2 Enable Remote IO Receiver: 01 06 00 F6 00 01 A8 38
3 Enable Remote IO Sender : 01 06 00 F5 00 01 58 38